Fireproof glass is a safety glass that meets certain fire resistance and thermal insulation requirements in accordance with relevant national regulations,and has functions such as rapid expansion of spreading fires,smoke isolation,and thermal insulation.But some businesses,in order to"take a share"of the fireproof glass market,do not hesitate to lose their conscience and use fake"fireproof glass"to seek illegitimate benefits.In order to safeguard the fire safety of public buildings,in addition to selecting high-quality fireproof glass,for glass deep processing enterprises,it is also necessary to carefully choose production and testing equipment for fireproof glass.
So,how can glass deep processing enterprises choose fire resistant glass inspection furnaces to self inspect the quality of glass and avoid unnecessary economic losses for the detection of fire resistant glass?
Currently,there are not many companies in China that can provide customized services for fireproof glass inspection furnaces,while Luoyang Gangxin is interested in this blue ocean market.With its strong technical background and resource chain in the manufacturing of glass deep processing equipment,Luoyang Gangxin Subsidiary(Luoyang Jieman)specializes in providing customized services for fire resistant glass inspection furnaces for deep processing enterprises.
The recommended evaluation criteria are as follows:
1.The design of the fireproof glass inspection furnace meets the requirements of EN1363-11363-2 curve and ISO 834 standard for fire resistance performance testing of building material components.The temperature tested in this furnace can reach up to 1250℃.
2.The temperature rise curve of the fireproof glass inspection furnace fully meets the temperature rise curve of GB15763.1-2001"Safety Glass and Fireproof Glass for Building Use",that is,the temperature inside the test furnace changes with time,and its variation law meets the following functional relationship:
T-T0=345lg(8t+1)
In the formula:T-average furnace temperature at the time of heating up to t
T0-initial temperature in the furnace,which should be within the range of 5℃-40℃.t-time experienced during the test,min.
3.The criteria for the fireproof glass inspection furnace include:
1)GB/T9978.1-2008"Fire resistance test methods for building components"
2)GB12955-2008"Fire doors"
3)GB16809-2008"Fireproof Windows"
4)GB15763.1-2009"Safety Glass for Building Purposes"Fire resistant glass
5)GB12513-2006"Fire resistance test methods for glazed components"
6)GBT38252-2019"Experimental Method for Fire Resistance Integrity of Building Doors and Windows"
7):IS0834-1-1999 EU Standard
8):EN1363-1-2012 International Standard
Red represents the actual temperature curve,while black represents the standard temperature curve
The Gangxin fireproof glass inspection furnace can inspect single piece fireproof glass(Class C),composite insulated fireproof glass(Class A),and fireproof windows.