Products

  • Fire-resistant Glass Test Oven
Fire-resistant Glass Test Oven
Our furnace working for Fire-resistant glass, integrity-only fire-resistant glass, laminated fire-resistant door/window etc.

Product Description

Fire-resistant glass Test oven

Our furnace working for Fire-resistant glass, integrity-only fire-resistant glass, laminated fire-resistant door/window etc.


Production under national standard (GB/T9978.1-2008GB/T 9978.1、GB/T 9978.8、XF 714. GB/T 8478、 GB/T 38252、GB/T 7633、GB/T12513, GB 12955, GB 14102. GB/T 15930 XF 533), meet the demands for self-test, Third parts test, official test.


Meet national requirements about the steady upward curve of temperature;


Meet international requirements about The pressure range requirements for initial combustion and stable combustion;


For different requirements, optional add more temperature measurement point, smoke extraction & dedusting system, data copies etc.


Fuel can use natural gas, LPG etc.


Meet and exceed the national standard requirements, new add safe ignition control system.


Product specifications:


1. Use special insulation board as gate, no need firebrick. For different size glass test just adjust gate size, convenient and efficient.


2. Light-weight and good thermal insulation performance, suitable for long distance transportation, no need site operation.


3. Accurate temperature control and perfect coincidence with the required curve.


According to (meet) the Standard:


1: GB/T9978.1-2008 Fire-Resistance Tests-Elements of Building Construction.


2: GB12955-2008 fire resistant doorsets.


3: GB16809-2008 Fire resistant windows.


4: GB15763.1-2009 Safety glazing materials in building---Part 1: Fire-resistant glass.


5: GB12513-2006  Fire-resistance tests-Elements of building construction-Glazed elements.


6: GBT38252-2019    Test method of fire-resistant integrity for building windows and doors.


7: IS0834-1-1999  EU Standard.


8: EN1363-1-2012  International standard.